Beberapa Contoh Sensor Gas

 TGS2442   ( Carbon Monoxide (CO)  )

Gas: CO
Measurement range: 30 ~ 1000ppm
Resistance at 100ppm: 13.3 ~ 133kΩ
Sensitivity: 0.13 ~ 0.31 (ratio between the resistance at 300ppm and at 100ppm)
Supply voltage: 5V ±0.2V DC
Operating temperature: -10 ~ +50ºC
Response time: 1 second
Minimum load resistance: 10kΩ
Average consumption:3mA

 TGS4161

Gas: CO2
Measurement range: 350 ~ 10000ppm
Voltage at 350ppm: 220 ~ 490mV
Sensitivity: 44 ~ 72mV
Supply voltage: 5V ±0.2V DC
Operating temperature: -10 ~ +50ºC
Response time: 1.5 minutes
Average consumption: 50mA

 SK-25

Gas: O2
Measurement range: 0 ~ 30%
Output range: Approximately 0 ~ 10mV
Initial voltage: 5.5 ~ 8.8mV
Operating temperature: 5 ~ +40ºC
Response time: 15 seconds
Consumption: 0μA

MiC-2710

Gas: NO2
Measurement range: 0.05 ~ 5ppm
Air resistance: 0.8 ~ 8kΩ (typically 2.2kΩ)
Sensitivity: 6 ~ 100
Supply voltage: 1.7 ~ 2.5V DC
Operating temperature: -30 ~ +85ºC
Response time: 30 seconds
Average consumption: 26mA

 TGS2444

Gas: NH3, H2S
Measurement range: 10 ~ 100ppm
Resistance at 10ppm: 3.63 ~ 36.3kΩ
Sensitivity: 0,063 ~ 0.63
Supply voltage: 5V ±0.2V DC
Operating temperature: -10 ~ +50ºC
Response time: 250ms
Minimum load resistance: 8kΩ
Average consumption: 12mA

 TGS2611

Gas: CH4, H2
Measurement range: 500 ~ 10000ppm
Resistance at 5000ppm: 0.68 ~ 6.8kΩ
Sensitivity: 0.6 ± 0.06
Supply voltage: 5V ±0.2V DC
Operating temperature: -10 ~ +40ºC
Response time: 30 seconds
Minimum load resistance: 0.45kΩ
Average consumption: 61mA

TGS2610

Gas: CH3CH2OH, CH4, C4H10, H2
Measurement range: 500 ~ 10000ppm
Resistance at 1800ppm (isobutane) 0.68 ~ 6.8kΩ
Sensitivity: 0.56 ± 0.06
Supply voltage: 5V ±0.2V DC
Operating temperature: -10 ~ +40ºC
Response time: 30 seconds
Minimum load resistance: 0.45kΩ
Average consumption: 61mA

TGS2600

Gas: C4H10, CH3CH2OH, H2, CO, CH4
Measurement range: 1 ~ 100ppm
Air resistance: 10 ~ 90kΩ
Sensitivity:0.3 ~ 0.6
Supply voltage: 5V ±0.2V DC
Operating temperature: -10 ~ +40ºC
Response time: 30 seconds
Minimum load resistance: 0.45kΩ
Average consumption: 46mA

TGS2602

Gas: C6H5CH3, H2S, CH3CH2OH, NH3, H2
Measurement range: 1 ~ 30ppm
Air resistance: 10 ~ 100kΩ
Sensitivity: 0.15 ~ 0.5
Supply voltage: 5V ±0.2V DC
Operating temperature: +10 ~ +50ºC
Storage temperature: -20 ~ +60ºC
Response time: 30 seconds
Minimum load resistance: 0.45kΩ
Average consumption: 61mA

TGS2620

Gas: CH3CH2OH, H2, C4H10, CO, CH4
Measurement range: 50 ~ 5000ppm
Resistance to 300ppm of Ethanol: 1 ~ 5kΩ
Sensitivity: 0.3 ~ 0.5
Supply voltage: 5V ±0.2V DC
Operating temperature: -10 ~ +40ºC
Response time: 30 seconds
Load minimum resistance: 0.45kΩ
Average consumption: 46mA

MiCS-2610

Gas: O3
Measurement range: 10 ~ 1000ppb
Air resistance: 3 ~ 60kΩ (typically 11kΩ)
Sensitivity: 2 ~ 4
Supply voltage: 1.95 ~ 5V DC
Operating temperature: -30 ~ +85ºC
Response time: 30 secondss
Average consumption: 34mA

MiCS-5521

Gas: CO, Hydrocarbons, Volatile Organic Compounds *
Measurement range: 30 ~ 400ppm
Air resistance: 100 ~ 1000kΩ
Sensitivity: 1.8 ~ 6 (typically 3, ratio between the resistance at 60ppm and at 200ppm of CO)
Supply voltage: 2.1 ~ 5V DC
Operating temperature: -30 ~ +85ºC
Response time: 30 seconds
Average consumption: 32mA

Advertisements

About pccontrol

Berisi Tutorial Menggunakan PC untuk mengontrol Peralatan dengan cara mudah & praktis untuk pemula.

Posted on 23/11/2011, in Tips & Trik. Bookmark the permalink. Leave a comment.

Komentar ,Saran atau Pertanyaan

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: